Prewarning for Flash Space Exhaustion

Product Line: Carrier IP product line                 Product Family: PTN

Summary: When an OptiX PTN 950 NE is configured with two system control boards

(active and standby),the license modules on the system control boards accumulate the board debugging

information. The accumulated debugging information exhausts the space of the flash memory, leading

to a failure to save the configuration dataand back up the NE database.

 

[Problem Description]

Trigger conditions:

The OptiX PTN 950 NE uses two system control boards which run the V100R002C01SPC100 NE

software.

Symptom: The standby system control board exhausts the flash memory space at a speed two times

faster than the active system control board. Therefore, the fault first occurs on the standby system

control board.

During the periodical backup of the NE database, if the flash memory has insufficient free space,

the system control board reports a DBMS_ERROR alarm. And also lead to memory leaks, if the

memory leak reaches the threshold, then reported MEM_OVER alarm.

Incremental files are generated when configuration data is delivered or when dynamic services

are configured.

If the flash space becomes insufficient during the process of generating incremental files, the

system control board may fail to generate these incremental files. When this occurs, the NE is

reset.

During an NE upgrade, when the NE detects that the free space on the flash memory is

insufficient to save the new software, the NE upgrade fails.

 

Identification method:

The NE type is OptiX PTN 950 and the NE version is V100R002C01SPC100.

The NE uses two system control boards.

 

[Root Cause]

The license module of the system control board software has a defect in data processing.

Due to this defect, the debugging information about the active and standby system control

boards continuously accumulates, exhausting the space of the flash memory. The debugging

information occupies 1 MB flash space every 20 days for the active

system control board but every 10 days for the standby system control board. (The debugging

information has no impact on the device functions and applications.)

 

[Impact and Risk]

The active and standby system control boards run out of the flash space.

When the NE database is being backed up, if the free space on the flash memory becomes

insufficient, the database will fail to be backed up. Then the new configuration cannot

persist and may be lost once the NE is reset. And also lead to memory leaks, if the memory

leak reaches the threshold, then reported alarm. After running out memory will cause the

control board reset.

If the free space on the flash memory becomes insufficient during the process of generating

incremental files, then the files will fail to be generated, causing the NE to be reset.

During an NE upgrade, if the free space is insufficient, the NE will fail to load the new

software and as a result the NE upgrade will fail.

 

[Measures and Solutions]

Recovery measures:

When a DBMS_ERROR or MEM_OVER alarm is reported, do as follows:

Run the following commands to check whether there is an HBUMSG.TXT file on the

active and standby system control boards:

sftm-show-dir:7,”ofs1/license”

sftm-show-dir:8,”ofs1/license”

If there is an HBUMSG.TXT file on the two boards, delete the file by running the

following commands:

sftm-delete-file:7,”ofs1/license/HBUMSG.TXT”

sftm-delete-file:8,”ofs1/license/HBUMSG.TXT”

Manual backup database

dbms-copy-all:drdb,fdb;

If it is MEM_OVER Soft reset the alarm control board

cfg-reset-board:$the slot of the alarm control board,soft

When the system control board reset, do as follows:

For a failure to synchronize data between the active and standby system control boards, run

the following command on the active system control board:

sm-set-nebusy:0,0,0,0,none

 

Run the following commands to check whether there is an HBUMSG.TXT file on the active

and standby system control boards:

sftm-show-dir:7,”ofs1/license”

sftm-show-dir:8,”ofs1/license”

If there is an HBUMSG.TXT file on the two boards, delete the file by running the following

commands:

sftm-delete-file:7,”ofs1/license/HBUMSG.TXT”

sftm-delete-file:8,“ofs1/license/HBUMSG.TXT”

If the new configuration data is lost, the relate services may affect, please reconfigure the

relate services.

 Workarounds:

Use the SmartKit Inspector to periodically perform preventive maintenance inspections

(PMIs) of

NEs of the specified version (V100R002C01SPC100).You are advised to perform the PMI

every three months.

On the live network the version of the SmartKit Inspector is V100R006C00. Before performing

a PMI, use the automatic upgrade function to upgrade the tool to the CN-PTN Box=P004 patch

version, the later version Inspector also has the similar item.

After installing the CN-PTN Box=P004 patch, load the R6FP005BP004_PreUpgrading_checking

Template.xmlfile to the SmartKit Inspector to perform the PMI.

 Preventive measures:

Install the V100R002C01SPH102 patch or upgrade the NE to a later version.