Issue Description
Q:
MA5600T( MA5600V800R005C32B138) has 2 PRTE one of them is
damaged so how can we check it from command line
Alarm Information
ALARM 2849 FAULT MAJOR 0x15411026 ENVIRONMENTAL
2010-08-12 10:04:24 DST
ALARM NAME : Fan power fault alarm
PARAMETERS : FrameID: 0 EMU ID: 0 Digital ID: 0 EMU Type: FAN
Name: Power fault
Name: Power fault
DESCRIPTION : Fan power fault alarm
CAUSE : Power fault
ADVICE : Check power
Handling Process
A:
About the querying about the power board through command line please check below
commands :
If the two board boards is normal:
MA5600T(config)#interface emu 0
MA5600T(config-if-fan-0)#display fan
{ alarm<K>|environment<K>|system<K> }:alarm
Command:
display fan alarm
EMU ID: 0
—————————————————————————-
Alarm name Alarm state
—————————————————————————-
Read temperature fault Normal
Fan block Normal
Temperature high Normal
Power fault Normal
—————————————————————————-
If one of the power board is failure or does not exists
MA5600T(config-if-fan-0)#display fan alarm
EMU ID: 0
—————————————————————————-
Alarm name Alarm state
—————————————————————————-
Read temperature fault Normal
Fan block Normal
Temperature high Normal
Power fault Alarm
—————————————————————————-
Root Cause
null
Suggestions
Null
Comments are closed