How to Upgrade the LSW Chip of the H801SCUN Board

H801SCUN is a control board for the MA5600T and uses the BCM56820 LAN switch chip.

After the hardware of the BCM56820 LAN switch chip is upgraded (that is, the BCM56820

LAN switch chip of a new hardware version is used), the software of the H801SCUN board

needs to be changed accordingly. It is learnt that from Mar. 2010, the H801SCUN board to

be delivered will use the LAN switch chip of Ver.B. In this case, if the software version of the

H801SCUN board is earlier than V800R006C02SPC110, the H801SCUN board will fail to

start.

Sub-product lineAccess                     ProductMA5600T

 

Problem Description

Trigger condition: 

In terms of the H801SCUN board (the LAN switch chip used is of Ver.B) to be delivered from

Mar. 2010,

1. If you downgrade the H801SCUN board to a version earlier than V800R006C02SPC110,

the H801SCUN board will fail to start.

2. If you delete the patch of V800R006C02SPC110, the H801SCUN board fails to start.

Problem phenomena: 

When the H801SCUN board fails to start, the following information is displayed:

Transferring control to the loaded program…OK!

Starting system application init……successfully!

Starting system configuration data init…successfully!

Drv_Lsw_Init: Drv_StackInit return error!

PHY initial step 2  error!  —> Init LSW card error!

A Fatal Error Occured!!! System Must be reboot!!

 

Judge method: 

1. If you downgrade the H801SCUN board to a version earlier than V800R006C02SPC110

2. If you delete the patch of V800R006C02SPC110, the H801SCUN board fails to start

 

Cause Analysis

When the hardware of the BCM56820 LAN switch chip used by the H801SCUN board is

upgraded from Ver.A to Ver.B, the software of the H801SCUN board is incorrect.

 

Impact and Risk

The H801SCUN board fails to start.

 

Measures and Solutions

Recover Measures:

Upgrade the software version of the H801SCUN board to V800R006C02SPC110 or later.

 

Avoidance Measures:

None

 

Solution:

Scenario 1: The software version of the H801SCUN board is downgraded from

V800R006C02SPC110 to V800R006C02SPC100, and as a result the H801SCUN board fails

to start.

If the SPH110 hot patch is not deleted, during the H801SCUN board startup process, reload

the V800R006C02SPC110 version during the extended BIOS booting.

Operation: In the following stage,

The last update date of extended BIOS is : Feb 16 2009, 11:29:49

Extended BIOS version is 105

Press <D> key to stop auto-boot    0              //Input d.

Load the package file of V800R006C02SPC110 through TFTP.

Scenario 2: The SPH110 hot patch of V800R006C02SPC110 is deleted, and as a result the

H801SCUN board fails to start.

In such a condition, load the firm file to the H801SCUN board. The firm file is not available

to technical support engineers. Therefore, contact the MA5600T-related R&D engineer

Li Chao (67686) for a solution.

 

Disposal for Replaced Material:

None

 

Reconstruction Scope and End time

The software version of the H801SCUN board on the current network is upgraded to

V800R006C02SPC110 or V800R007C00 or their later versions.

 

Reconstruction Guidance]

None

Attachment

None

 

Categories:

Comments are closed