Issue Description
Customer reported one issue. He bought ES1D2X08SED4 board but cannot
find the port. There are two S7700 swithes. One is ok and another is not ok.
On first device:
On second customer could find the 10GE port:
Alarm Information
None
Handling Process
1. Check board status and find it is unregistered.
Slot Sub Type Online Power Register Alarm Primary
– – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
2 – ES0DG48CEAT0 Present PowerOn Registered Normal NA
3 – – Present PowerOn Unregistered – NA
7 – ES0D00SRUA00 Present PowerOn Registered Normal Master
2. It is present and poweron which means there is no problem about the
power system.
3. Check the logbuffer and get below information. I doubt the LPU version is
not compatible with MPU
Oct 9 2013 18:54:45 HW_01 %%01ALML/3/CPU_RESET(l)[54]:The canbus
node of LPU board[1/3] detects that CPU was reset.
Oct 9 2013 18:54:37 HW_01 %%01LOAD/4/LOAD_RESULT(l)[55]:Load result is “
The files of LPU board on slot 3 are the latest version, and would be reserved!
Startup download for LPU board on slot 3 finished.”.
Oct 9 2013 18:54:06 HW_01 %%01ALML/4/CAN_READY(l)[56]:The canbus node
of LPU board[1/3] is ready.
Oct 9 2013 18:54:05 HW_01 %%01LOAD/4/LOAD_CBUS(l)[57]:The load canbus
software information :
COMPARE SMS VERSION :read 0x06017300 file error.
Oct 9 2013 18:54:05 HW_01 %%01ALML/3/CANNODE_POWERON(l)[58]:
The canbus node of LPU board[1/3] is powered on.
4. Check the output of command “check version all”. Found the version is newer
and need to upgrade the system.The ES1D2X08SED4 is supported in V200R002C00
and later versions.
1/3 LPU CANBUS_SDR 0x6 0x0 Newer Recommend
5. After upgrade the version, LPU3 register successfully.
Root Cause
1. The board is not registered on S7700.
Suggestions
None