The-HARD_BAD-and-COMMUN_FAIL-alarms-on-the-AUX-board-of-the-OSN9800-M12

The HARD_BAD and COMMUN_FAIL alarms on the AUX board of the OSN9800 M12

Problem Description

The OSN9800 M12 report the HARD_BAD alarm and COMMUN_FAIL alarms on the AUX board

The HARD_BAD and COMMUN_FAIL alarms on the AUX board of the OSN9800 M12-1

Problem Analysis

Device type:

The HARD_BAD and COMMUN_FAIL alarms on the AUX board of the OSN9800 M12-2

1. Checking current NE package loading status , which already finish the package loading:

The HARD_BAD and COMMUN_FAIL alarms on the AUX board of the OSN9800 M12-3

2. Analysis the COMMUN_FAIL alarm , the parameter is 0x1,0x0,0x4, which indicate the communication with slot 1-74 F3AUX failed.

The HARD_BAD and COMMUN_FAIL alarms on the AUX board of the OSN9800 M12-4

3. And check the HARD_BAD alarm, the parameter indicate that the Lan-Switch Link of the F3AUX boards in slots 1-74 is abnormal, which is an intra-board fault.

The HARD_BAD and COMMUN_FAIL alarms on the AUX board of the OSN9800 M12-5

Root Cause

According to the preceding analysis, the HARD_BAD and COMMUN_FAIL alarms were reported because the F3AUX board in slots 1-74 was faulty.

 

Solution Description

1.  apply the spare board TMF3AUX01*1 pcs(BOM: 03033VNA) and prepare a new cable;

The HARD_BAD and COMMUN_FAIL alarms on the AUX board of the OSN9800 M12-6

2. Backup the database and then apply the operation windows;

3. Go to the site and then check if the cable between 0-74 CTU and 1-74 AUX is normal or not, if the cable is normal, please replace the board in slot 1-74 and wait for the board synchronize and then check if the alarm clear or not.

Note: After plug out the board, please make sure there is no bent pin or foreign object in the backplane, or the new board will be damaged.

Comments are closed