Issue Description
when plug RJ Module to 25GE interface of NE8K-X4, the interface shows down
Handling Process
enter interface view, try to change the port mode, but only can change to 25GE or 10GE, can’t change to GE mode, then try to plug the RJ45 module to the interface, shows down
confrimed with R&D, need configure the port group to 10GE-1GE mode, then the interface in this group can be configured to 10GE or GE
Root Cause
Configuration issue
Solution
enter slot view, then configure port group to 10GE-1GE mode
##slot x
##port-mode card-id x group-id x 10GE-1GE
then enter interface view, configure the interface to GE mode
## port-mode 1GE