Issue Description
Q:
In a Customer meeting customer ask about us how many RT (remote frame RSU_HABD) we can add to COT( PVMB_HABD).
Alarm Information
Failure: Resource of HW error
Handling Process
A:
We have to confirm the limitation of the Remote frame ( RSU with HABD frame) per PVM board ( Main HABD with PVMB).
We check the document,no related information found then we try to add the frame manually in the system.
We can add the 32 remote frame successfully but when adding the next frame ie.33 it prompt one error message that HW-resource error.
After doing the above operation we came to know that PVMB supports on 32 remote frames.
Root Cause
We have to confirm the value of the Remote frame ( RSU with HABD frame) we try to search the same in support site and document but it was not present there.
Then we try to check it in the system because we have to confirm the value ASAP.
Suggestions
PVMB ( PVMB with master frame HABD)supports on 32 Remote frame ( RSU with HABD Frame).
Comments are closed