Prewarning for Maintenance of the AC Power Board on the MA561x

Summary: When replacing the AC power board PAIA/PAIB on the MA5610/MA5616, if the operator

removes the power board without powering off it beforehand (removing the 220 V AC power connector

on the panel), there are potential safety hazards.

Product Line:  Access Network                   Product Model: MA5616

Keywords: MA5610/MA5616   PAIA  PAIB  AC power board  security specifications

Problem Description 

Trigger conditions

When replacing of the AC power board PAIA/PAIB on the MA5610/MA5616, the operator removes the AC

power board without powering off the board beforehand (disconnecting the 220 V AC power plug from the

panel).

Symptom

Removing the power board before disconnecting the 220 V power plug from the board panel causes

potential safety hazards.

Identification method

The MA5610s/MA5616s installed with the PAIA or PAIB power boards that are delivered to sites before

September 1, 2009 are affected.

 

Root Cause

The safety specifications of the H831PAIA/H831PAIB AC power boards used on the MxUs cannot fully

meet the requirements, which may produce potential safety hazards to operators who remove the power

boards without complying with safety rules.

 

Impact and Risk

There are potential safety hazards.

 

Measures and Solutions

Preventive measures

The safety specifications of the AC power boards delivered after September 2009 have been strengthened.

Recovery measures

Use the inspection tool to check the boards on the live network. Rectify the board with potential safety

hazards.

For the inspection tool script, detailed delivery data, rectification method, contact CS coordinator Xue

Guoqiang (Employee ID: 98735) for China market and Nie Bo (Employee ID: 92548) for markets outside

of China.

 

Prewarning Expiration Condition

This prewarning will expire after the board check is complete.

Categories: