The SSN1EGS4 is a 4-port Gigabit Ethernet Switching Processing Board with Part Number03051249.The SSN1EGS4 is available in three functional versions, namely, N1, N3 and N4.
Here is the solution of the problem:
【Problem Summary】OSN3500 NE degrade fail(V1R10 > V1R9)
【Problem Details】OSN3500 use simulation package loading from V1R10C03SPC203 down V1R9SPC200, N4EGS4 board fails to start after activation, leading to activation of overtime
[13:59:35.734872 11-112] recv:
BOARD-VERSION
Bid BD-TYPE RVER DVER HVER ONLINE-FLAG
8 ssn4egs4 0x02 0x30 0x0102 online
Total records :1
[13:59:35.791472 11-112] recv:
#11-112:szhw [][][2014-01-29 13:59:32+09:00]>————————————————————-
:optp:8,0,1b,1,1,19;
[13:36:31.170503 11-112] recv:
Send Message Fail!
[13:41:45.725237 11-112] recv:
failed! cmd:0x0119 error:0x0001 no error message
3、Laboratory can reproduce the problem, the board does not start properly after the downgrade, the analysis is a certain configuration can not smooth downgrade that leads data board does not start properly.
Some configuration of data board can not be smooth downgrade, so be sure to hard reset when downgrading re-initialize the configuration, even without updating the logical file also needs a hard reset.