EGS4

Solution ——N4EGS4 activation timeout when OSN3500 use simulation package loading from V1R10 to V1R9

The SSN1EGS4 is a 4-port Gigabit Ethernet Switching Processing Board with Part Number03051249.The SSN1EGS4 is available in three functional versions, namely, N1, N3 and N4. 

Here is the solution of the problem:

【Problem Summary】OSN3500 NE degrade fail(V1R10 > V1R9)

【Problem Details】OSN3500 use simulation package loading from V1R10C03SPC203 down V1R9SPC200, N4EGS4 board fails to start after activation, leading to activation of overtime

:cfg-get-bdversion:8
[13:59:35.734872 11-112] recv:
BOARD-VERSION
Bid BD-TYPE RVER DVER HVER ONLINE-FLAG
8 ssn4egs4 0x02 0x30 0x0102 online
Total records :1
[13:59:35.791472 11-112] recv:
#11-112:szhw [][][2014-01-29 13:59:32+09:00]>
————————————————————-
:optp:8,0,1b,1,1,19;


[13:36:31.170503 11-112] recv:
Send Message Fail!

:optp:8,0,1b,1,1,19;


[13:41:45.725237 11-112] recv:
failed! cmd:0x0119 error:0x0001 no error message

Some configuration of data board can not be smooth downgrade, so be sure to hard reset when downgrading re-initialize the configuration, even without updating the logical file also needs a hard reset.

【Resolution Details】There are two ways: 1simulation package upgrade task to force load FPGA filemake a hard reset board downgrading2after the downgrade failed hard reset using optp command once again, the specific command: optp: 8,0,1 b, 1 ,1,14,0 (first parameter is the board id, modify the corresponding hexadecimal value to other unchanged)When the data board downgrading requires a hard resetor it may appear board not start properly.