The TN11OAU101 at the transmit end reports the MUT_LOS alarm because the optical attenuation
of the M40V board is not adjusted.
Product
Fault Type
Service Interruption
Automatic Power Equilibrium (APE)
Optical Amplifier Unit
MUT_LOS
Symptom
At the ROADM station consisting of the OptiX OSN 6800 V1R2, the signal flow in the wavelength
add direction is as follows: L4G->M40V->WSM9->OAU->FIU. After the internal logical fiber
connections are complete at the NE, create the single-station optical cross-connections and select
the automatic optical power adjustment function. Then, the T2000 prompts that the creation is
successful. The OAU board, however, reports the MUT_LOS alarm. No alarm is generated on
other boards.
Cause Analysis
The OPA supports only the WSD9, WSM9, RMU9, and ROAM boards. In the case of other boards
supporting the setting of attenuation (VA1/M40V/D40V), the OPA does not set the attenuation.
Thus, you need to set the attenuation. During the calculation, OPA regards the attenuation as
zero (0) and the changes in the attenuation of the boards does not trigger the re-adjustment by
the OPA.
By default, the VA1, M40V, and D40V take the maximum attenuation for each channel. Hence,
when the OPA function is started, the light from the L4G does not enter the OAU after passing
the M40V because the attenuator of the M40V is not adjusted.
Procedure
1. Adjust the M40V on the T2000 and set the attenuation value of the corresponding channel
to 0 dB. Then, the MUT_LOS alarm is cleared.
Reference Information
In certain scenarios, the attenuation of certain channels of the M40V, D40V, VA1, and VA4
boards needs to be set manually. At the station that is configured with the M40V, D40V, VA1,
or VA4, set the attenuation value of the optical channel of the board manually to ensure the
availability of the optical channel. This is very important for the ASON feature to trigger
rerouting in the WDM network.