Issue Description
OSN 1500 R1PCXLN board fails to query optical power, the optical power can not
be reported normally , the SCC version is 5.36.30.15.
Alarm Information
NULL
Handling Process
Warm reset the R1PCXLN board
Root Cause
1、The problem can be recured in the lab, once the line board type is changed, the optical
power can not be reported.
2、When R1PCXLN board type is changed, the line board can be used by multi-board ID .
This operation could disable optical power report module due to the software BUG, lead
to the optical power can not be reported normally.
Suggestions
1、This handling method is a temporary way to avoid this problem, if you change the
R1PCXLN board type, the optical power will not be reported normally. The root method
is upgrade patch, the patch have not come forth now. Once the patch can be acquired,
I will update this case.
2、The related product version is V1R9C03 and V2R11C00.