When OSN 1500 R1PCXLN board fails to query optical power due to software BUG?

Issue Description

OSN 1500 R1PCXLN board fails to query optical power, the optical power can not

be reported normally , the SCC version is 5.36.30.15.

Alarm Information

NULL

Handling Process

Warm reset the R1PCXLN board

Root Cause

1、The problem can be recured in the lab, once the line board type is changed, the optical

power can not be reported.

2、When R1PCXLN board type is changed, the line board can be used by multi-board ID .

This operation could disable  optical power report module due to the software BUG, lead

to the optical power can not be reported normally.

Suggestions

1、This handling method is a temporary way to avoid this problem, if you change the

R1PCXLN board type, the optical power will not be reported normally. The root method

is upgrade patch, the patch have not come forth now.  Once the patch can be acquired,

I will update this case.

2、The related product version is V1R9C03 and V2R11C00.

Tags: